Mt. Adams K-8 School Replacement (Sub-Bids To Fowler General Construction) - Harrah

Work includes demolition of existing site elements, new site work, paving (hard surface) revisions, and new building construction. The overall existing building area is approximately 103,000 square feet of new addition+ site work. 2. Construction elements include conventional reinforced cast-in-place concrete foundations, floor slabs, and wood and masonry construction. Site work elements are required to accommodate the new building construction work. 3. Exterior doors are Hollow Metal door/frame assemblies. Exterior glazing systems include aluminum windows and aluminum store front wall door/window systems. Exterior glazing is low-e tempered glass with solar bonze tint. 4. Interior building construction elements include gypsum board attached to wood or wood framing. Interior doors are solid core wood doors in hollow metal frames. 5. Interior finishes include painted walls and other surfaces, polished concrete, carpeting, walk-off carpeting, resilient flooring, ceramic tile walls, ceramic mosaic tile floors, gypsum boards soffits, and suspended acoustical ceilings. 6. Specialties, equipment and furnishings include marker boards, toilet accessories, cabinets and accessories, signs and miscellaneous specialties. 7. Mechanical work includes plumbing systems and fixtures, heating and air conditioning systems. Site mechanical work includes service piping and lines for water and sanitary sewer and fire sprinkler system. 8. Electrical work includes distribution systems, lighting fixtures, fire alarm work, data/phone work. 9. Site work includes plumbing storm drainage systems, water system, earthwork for new improvements, concrete walkways asphalt paving and landscape, irrigation work and fencing, accessories and the like.
  Addendum #1 (click to expand/collapse)
Name Size
17003.2 Addendum 1 - Final 10.5 MB
  Addendum #2 (click to expand/collapse)
Download section as a Zip file free of charge
Name Size
0.Addendum - Architect 352.5 KB
1.27 11 00 Com Equip Rooms and Fittings 177.8 KB
2.27 15 13 Com Horizontal Cabling 227.8 KB
3.844400-CIVIL -C1-9 743.8 KB
4.A.01 - Addendum 2 53.3 KB
5.A.02 - Addendum 2 71.4 KB
6.A.03 - Addendum 2 54.3 KB
7.A.04 - Addendum 2 64.4 KB
8.A.05 - Addendum 2 48.8 KB
9.A.06 - Addendum 2 68.6 KB
10.A10.08 - Door Schedule 88.4 KB
11.A10.09 - Door Schedule 88.2 KB
12.8444_S17-34 1.9 MB
13.M0.1 - Expansion tank revision - schedule 68.0 KB
14.M0.2 - Expansion Tank drawing 88.2 KB
15.17003.2_e_200129_addendum 2 5.9 MB
  Addendum #3 (click to expand/collapse)
Name Size
Mt Adams Add 3 14.6 MB